Model:
DNS-3100 - 2U Dual Active 4G Fibre to SAS/SATA RAID

The DataON™ DNS-3100 the Dual Active Expandable 4G Fibre Channel RAID Stroage Solution, designed for high-impact and high-volume storage environments. The DNS 3100™ is utilizing Dual Active-to-Active hot-swap componets, such as dual Fibre RAID controllers, dual high speed cooling fan modules and dual redundant power supplies, which provide data accessibility and availability around the clock. A standard 2U rackmount design supports up to 12 high-performance SAS and cost-effective SATA disks, with total capacity of 18TB and up to total 36TB storage by adding another 12 disks JBOD expansion. The DNS 3100 is an ideal Dual Active Fibre Channel RAID storage solution for professional storage applications that require critical data protection and continuous data processing 24 hours a day and 7 days a week all year long.

Dual Active-to-Active 4G Fibre Channel Controllers
DNS 3100™ controllers are featuring a next generation Dual Active-to-Active technology that capable of sustaining a high speed data transfer rate, and offering a cutting edge data redundancy, which provides complete storage protection. The dual Fibre RAID controllers also support a host of RAID advanced functions such as RAID level 0, 1, 10, 3, 5 & 6, Global or Dedicate Hot Spare and Automatic RAID Reconstruction.


Quad SFP Fibre Channel Interfaces
The DNS 3100™ provides up to 12 SAS/SATA disks and features Four (Two per Controller) 4G Fibre Channel,compatible with industry standard SFP interface with copper or optical connection, which is a high-speed network technology that's widely deployed in post, and maximizes disk performance for a broader range of storage possibilities.


Zero-Down-Time
DNS 3100™ comes with 2 x 500 watt hot-swappable redundant power supplies that protect the system from unexpect AC surge. The two power supplies share system's power loading and ready to take over the full system power loading if one of the power fails. With the hot-swap feature, the system can remain in operation while the replacement is taking place to ensure system availability and provide zero-down-time.

  • Redundant Controllers or Single Controller Configuration
  • Active-Active LU Access
  • Hot Swappable Controllers
  • Active-Active Software Cache Mirroring
  • Up to 4GB Cache Memory
  • Battery Backup Write Cache for 72 hours
  • Four 4G FC Host Interface
  • Up to 32 Concurrent Hosts
  • Redundant Disk Access Path for Both SAS/SATA Hard Disks
  • Support RAID Levels: 0, 1, 10, 3, 5, 6
Host InterfaceTwo 4G FC ports on each Controller.
Hard Disk Interface:12 x dual ported SAS (3Gb/s) or SATAII hard disks with interposer board (1.5Gb/s or 3Gb/s)
Up to a maximum of 12 disks, provide 1.75 TB capacity with SAS hard disks and 6 TB capacity with SATAII hard disks per system.
For Daisy Chaining SAS JBODs, with a total maximum of 60 hard disks, provides 8.8 TB storage capacity with SAS hard disks or 30 TB capacity with SATAII hard disks.
Redundant, Hot Swappable Components2 RAID Control Modules
2 Power Modules
2 Cooling Modules
Up to 12 SAS/SATA II hard disks
Form FactorInternal Bays: 12 Hard Disks
Rack Mount: 19 in.
Dimensions: The chassis dimensions measured at 445 mm (W) X 87.4mm (H) X 596mm (D) (Sheet metal case only, not including bezel and rear module handle).
Management FeaturesWeb Based Management Interface
SMI-S Compliant
VSS, VDS Support
Online FW upgrade
Performance Monitor
SNMP
Email Alert
LED Indicators for RAID Control Modules, Power Modules, Cooling Modules, and Hard Disks Status.
Disk DrivesSAS
SATA / SATA II
3.5-inch form factor, 1.0-inch height
AC PowerInput Voltage: Auto ranging, 100-240 VAC
Input Frequency: 50-60Hz
Input Current: 100-240 VAC @ 9A
Output Power: 500 W
Operating EnvironmentOperating Temperature: 0 to 35 degree Celsius
Operating Humidity: 5% to 95% (non-condensing)
Altitude: -50 to 10,000 feet
Shock: 31G @ 2.6ms, ½ sine wave pulse
Vibration: 0.25G @ 3Hz to 200Hz
Electromagnetic Emissions StandardsFCC class A
CE Specifically requirements in effect July 1, 2001
VCCI for Japan
CCC for China
BSMI for Taiwan/CNS/3438
C-TICK for Australia and New Zealand
Safety StandardsUL/CUL: for U.S. with Canada / UL60950-1
TUV: for Germany / EN60950-1
CB (by TUV): IEC60950-1
BSMI: Taiwan / CNS14336
CCC: for China

Datasheet Area:

Click for datasheet   Download Click to download datasheet